High Voltage Heat Shrink Bus bar Insulation Tube
Summary for High Voltage Heat Shrink Bus bar Insulation Tube

 MPG High Voltage Heat Shrink Bus bar Insulation Tube can avoid short circuit fault caused by small animals such as mice, snakes etc. After using heat shrink bus bar insulation tube, it can avoid accidental injure to overhaul persons when they enter electriferous clearance by mistakes. Heat shrink bus bar insulation tube prevent bus bar from chemical corrosion effected by strong acid, alkali, salt etc.  Heat shrink bus bar insulation tube solve the problem of insulating among bus bars in bus duct , Heat shrink bus bar insulation tube provide excellent insulation performance to supply enquired flashover protection for the bas bar system. .
Color: Red, yellow, green, black

Specification Table of MPG High Voltage Heat Shrink Bus Bar Insulation Tube
Heat shrink bus bar insulation tube           Mode& specification(mm) Heat shrink bus bar insulation tube            Product specification(mm) Heat shrink bus bar insulation tube    adaptable width of the bus-bar(mm)
MPG10-C-25/10 MPG10-C-25/10 φ25×1000 20~25
MPG10-C-30/12 MPG10-C-30/12 φ30×1000 25~30
MPG10-C-40/16 MPG10-C-40/16 φ40×1000 35~40
MPG10-C-50/20 MPG10-C-50/20 φ50×1000 45~55
MPG10-C-65/26 MPG10-C-65/26 φ65×1000 60~70
MPG10-C-75/30 MPG35-C-75/30 φ75×1000 70~80
MPG10-C-85/34 MPG35-C-85/34 φ85×1000 85~95
MPG10-C-100/40 MPG35-C-100/40 φ100×1000 100~115
MPG10-C-120/48 MPG35-C-120/48 φ120×1000 120~130
MPG10-C-150/60 MPG35-C-150/60 φ150×1000 140~160
MPG10-C-180/72 MPG35-C-180/72 φ180×1000 170~190
MPG10-C-200/80 MPG35-C-200/80 φ200×1000 195~210
Note: 10 kV continuous length bus bar tube
Type Demonstration for MPG High Voltage Heat Shrink Bus bar Insulation Tube
 
Technical Data of MPG High Voltage Heat Shrink Bus bar Insulation Tube

No.

Heat shrink bus bar insulation tube                                      Test items

Heat shrink bus bar insulation tube                                    Standard requirements

Heat shrink bus bar insulation tube                                     Test result

1

1min phase-phase power frequency withstand test for the Heat shrink bus bar insulation tube

42kV no flash and no breakdown

42kV,1 min,no flash and no breakdown sample

2

phase-phase impulse voltage test for the Heat shrink bus bar insulation tube

75KV 15 times phase-phase impulse
withstand test of the positive
and the negative respectively, no flash and no breakdown

75kV 15 times phase-earth shock withstand
test of the positive and the negative
respectively; no flash and no breakdown sample

3

1min phase-earth power frequency withstand test for the Heat shrink bus bar insulation tube

42kV no flash and no breakdown

42kV,1 min, no flash and no breakdown sample

4

phase-earth impulse-voltage test for the Heat shrink bus bar insulation tube

75KV 15 times phase-earth impulse
withstand test of the positive and
the negative respectively; no flash
and no breakdown

75kV 15 times phase-earth shock withstand
test of the positive and the negative
respectively; no flash and no breakdown sample

5

temperature rise test for the Heat shrink bus bar insulation tube

the temperature rise of the copper
should not over the bare copper
s
when the insulated tube shrunk in
the below 40℃surrounding.

the temperature rise of the bare
copper: 47.7℃ the temperature rise
of the insulated copper bus-bar:41.4℃

6

Withstand test of the heat-shrinkable tube for the Heat shrink bus bar insulation tube

20kV, 1min no breakdown

20kV, 1min no breakdown