Summary |
|
Radiation co-connection
heat-shrinkable cable accessories is
the newest product of the national
cable accessories industry. The
product is the dimension, light in
the weight, reliable performance,
powerful adaptation, easily
installation and low price. It is
widely used in the
inside-and-outside direct and
intermediate terminal connection of
every kinds of power cable including
co-connection cable, plastics cable
and oil-connection cable. It also
can be used as the connection
accessories of the communication
cable and the insulated protection.
It is widely used in power supply of
the power, petroleun and chemical
industry, me-tallurgy and mine,
construction and shipbuilding. |
| |

Note: 0
in the specification of the cable
represents that the cable is
adaptable for 10-16mm2
cable,1 represents that the cable is
adaptable for 25-50mm2cable, 2
represents that the cable is
adaptable for 70-120mm2
cable, 3 represents that the cable
is adaptable for 150-240mm2cable, 4
represents that the cable is
adaptable for 300-500mm2cable. |
|
|
Specification Table of heat
shrinkable end caps: |
|
 |
|
10kV 1-core outdoor termination
10kV 3-core indoor termination
10kV 3-core outdoor termination |
|
|
35kV 1-core indoor termination
35kV 1-core outdoor termination
35kV 3-core indoor termination |
 |
|
35kV 3-core outdoor termination
10kV 1-core straight joint
10kV 3-core straight joint |
| |
|
Technical Data of 10kV Heat
Shrinkable Terminations and Straight
Joints |
|
Order
|
Test items
|
Standard requirements
|
Test result
|
|
1
|
1min power frequency
voltage test
|
45kV no flash and no
breakdown
|
45kv,1min,the
respectively phase of
the combination sample
has no flash and no
breakdown
|
|
2
|
load circulation test
|
conductor heated to
90~95≧,8h of
every circulation-5h
heated and
3h cooled, total 3
circulations
|
completes 3 load
circulations conforming
the
standard requirements
judge by the
following tests
|
|
3
|
partial discharge test
|
the discharge is not
above 20pC
when the voltage is
below 13kV
|
phase
|
yellow
|
green
|
red
|
|
PC the discharge
Acceptance
|
+2
|
+2
|
6
|
|
4
|
Impulse voltage test
|
105kV 10times of the
positive and
the negative
respectively, no flash
and no breakdown
|
105kV 10times of the
positive and the
negative
respectively, the
respectively phase of
the
combination sample has
no flash and no
breakdown
|
|
5
|
15min DC test of the
negative pole
|
52kV no flash and no
breakdown
|
52kv the respectively
phase of the 15min
combination sample has
no flash and no
breakdown
|
|
6
|
4h power voltage test
|
35kV no flash and no
breakdown
|
35kV the respectively
phase of the 4h
combination
sample has no flash and
no breakdown
|
|
|
Specification Table of Heat
Shrinkable Terminations and Straight
Joints |
|
1kV Heat
Shrinkable Termination and
Straight Joint for Cross
Linked Cable |
| |
|
Product name
|
Mode & specification
|
The applicable cable
section
mm2
|
|
1kV One-core Termination
|
TRSY-1/1,0
|
10-16
|
|
TRSY-1/1,1
|
25-50
|
|
TRSY-1/1,2
|
70-120
|
|
TRSY-1/1,3
|
150-240
|
|
1kV Two-core
Termination
|
TRSY-1/2,0
|
10-16
|
|
TRSY-1/2,1
|
25-50
|
|
TRSY-1/2,2
|
70-120
|
|
TRSY-1/2,3
|
150-240
|
|
1kV Three-core
Termination
|
TRSY-1/3,0
|
10-16
|
|
TRSY-1/3,1
|
25-50
|
|
TRSY-1/3,2
|
70-120
|
|
TRSY-1/3,3
|
150-240
|
|
1kV Four-core
Termination
|
TRSY-1/4,0
|
10-16
|
|
TRSY-1/4,1
|
25-50
|
|
TRSY-1/4,2
|
70-120
|
|
TRSY-1/4,3
|
150-240
|
|
1kV Five-core
Termination
|
TRSY-1/5,0
|
10-16
|
|
TRSY-1/5,1
|
25-50
|
|
TRSY-1/5,2
|
70-120
|
|
TRSY-1/5,3
|
150-240
|
|
|
|
|
Product name
|
Mode &
specification
|
The applicable
cable section
mm2
|
|
1kV
One-core
Straight Joint
|
JRSY-1/1,0
|
10-16
|
|
JRSY-1/1,1
|
25-50
|
|
JRSY-1/1,2
|
70-120
|
|
JRSY-1/1,3
|
150-240
|
|
1kV
Two-core
Straight Joint
|
JRSY-1/2,0
|
10-16
|
|
JRSY-1/2,1
|
25-50
|
|
JRSY-1/2,2
|
70-120
|
|
JRSY-1/2,3
|
150-240
|
|
1kV Three-core
Straight Joint
|
JRSY-1/3,0
|
10-16
|
|
JRSY-1/3,1
|
25-50
|
|
JRSY-1/3,2
|
70-120
|
|
JRSY-1/3,3
|
150-240
|
|
1kV Four-core
Straight Joint
|
JRSY-1/4,0
|
10-16
|
|
JRSY-1/4,1
|
25-50
|
|
JRSY-1/4,2
|
70-120
|
|
JRSY-1/4,3
|
150-240
|
|
1kV Five-core
Straight Joint
|
JRSY-1/5,0
|
10-16
|
|
JRSY-1/5,1
|
25-50
|
|
JRSY-1/5,2
|
70-120
|
|
JRSY-1/5,3
|
150-240
|
|
|
|
|
10kV Heat Shrinkable
Termination and Straight
Joint for Cross Linked Cable
|
Product name
|
Mode & specification |
The applicable cable section
mm2
|
|
10kV Three-core Indoor
Termination |
|
NRSY-10/3,1
|
25-50
|
|
NRSY-10/3,2
|
70-120
|
|
NRSY-10/3, 3
|
150-240
|
|
NRSY-10/3,4
|
300-500
|
|
10kV Three-core Outdoor
Termination |
|
WRSY-10/3,1
|
25-50
|
|
WRSY-10/3,2
|
70-120
|
|
WRSY-10/3,3
|
150-240
|
|
WRSY-10/3,4
|
300-500
|
|
10kV Three-core Intermediate connector |
|
JRSY-10/3,1
|
25-50
|
|
JRSY-10/3,2
|
70-120
|
|
JRSY-10/3,3
|
150-240
|
|
JRSY-10/3,4
|
300-500
|
|
|
|
|
35kV Heat
Shrinkable
Termination
and Straight
Joint for
cross linked
cable |
|
|
|
|
Product name
|
Mode & specification
|
mm2
The applicable cable section |
|
35kV One-core Indoor
Termination |
NRSY-35/1,1
|
50
|
|
NRSY-35/1,2
|
70-120
|
|
NRSY-35/1,3
|
150-240
|
|
NRSY-35/1,4
|
300-500
|
|
35kV One-core Outdoor
Termination |
WRSY-35/1,1
|
50
|
|
WRSY-35/1,2
|
70-120
|
|
WRSY-35/1,3
|
150-240
|
|
WRSY-35/1,4
|
300-500 |
|
35kV One-core Straight Joint
|
JRSY-35/1,1
|
50
|
|
JRSY-35/1,2
|
70-120
|
|
JRSY-35/1,3
|
150-240
|
|
JRSY-35/1,4
|
300-500
|
|
|
|
|
Product name
|
Mode & specification |
The applicable cable section mm2
|
|
35kV Three-core Indoor
Termination |
NRSY-35/3,1
|
50
|
|
NRSY-35/3,2
|
70-120
|
|
NRSY-35/3,3
|
150-240
|
|
NRSY-35/3,4
|
300-500
|
|
35kV Three-core Outdoor
Termination
|
WRSY-35/3,1
|
50
|
|
WRSY-353,2
|
70-120
|
|
WRSY-35/3,3
|
150-240
|
|
WRSY-35/3,4
|
300-500 |
|
35kV Three-core Straight Joint
|
JRSY-35/3,1
|
50 |
|
JRSY-35/3,2
|
70-120 |
| JRSY-35/3,3 |
150-240 |
| JRSY-35/3,4 |
300-500 |
|
|
|
|
|