Silicon Rubber Precast Outdoor and Indoor Termination |
Home
< Silicon rubber precast |
|
 |
|
| ¡¡ |
 |
| ¡¡ |
|
|
|
Silicon Rubber Precast Outdoor and Indoor Termination Summary |
|
Cold
shrinkage cable accessory is made by
imported LSR silicon rubber
material, that not only has good
electrical performance, it has lots
of physical feature as excellent
adding water performance, high
spring and long service life and so
on. The design, constant shrinking
press of the product keep close
combination with cable body and has
good waterproof performance, it is
especially suitable for using in
environment with high temperature,
cold, salt fog, moisture wet and
heavy pollution.
The cold shrinkage cable accessory
has omitted the trouble problem and
unsafe factor due to the thermal
shrinkage product using fire to
feat. Comparing with the thermal
shrinkage products the cold
shrinkage cable accessory adopts
support principle to take out the
support, then it will auto shrink
and reset. and does need heat so it
is called as cold shrinkage. it is
very easy to use |
|
Reliable insulation |
| Make
use of insulation and elasticity of
silicon rubber. Add the radial
stress to the cable after install.
keep "breath" with cable in order to tighted inner layer. The part of
stress control and main insulation
are compounded together. Solving the
problem of power fields collection,
for the cable screen discontinue
position and reliable insulation
,stability running. |
|
Specification |
|
Cable m©O
|
Specification indoor
|
Specification outdoor
|
|
6/10KV(6KV)
|
8.7/15KV(15KV)
|
1-CORES
|
3-CORES
|
1-CORES
|
3-CORES
|
|
35
|
25
|
NYZ-15/1.1
|
NYZ-15/3.1
|
WYZ-15/1.1
|
WYZ-15/3.1
|
|
50
|
35
|
NYZ-15/1.2
|
NYZ-15/3.2
|
WYZ-15/1.2
|
WYZ-15/3.2
|
|
70
|
50
|
NYZ-15/1.3
|
NYZ-15/3.3
|
WYZ-15/1.3
|
WYZ-15/3.3
|
|
95
|
70
|
NYZ-15/1.4
|
NYZ-15/3.4
|
WYZ-15/1.4
|
WYZ-15/3.4
|
|
120
|
95
|
NYZ-15/1.5
|
NYZ-15/3.5
|
WYZ-15/1.5
|
WYZ-15/3.5
|
|
150
|
120
|
NYZ-15/1.6
|
NYZ-15/3.6
|
WYZ-15/1.6
|
WYZ-15/3.6
|
|
185
|
150
|
NYZ-15/1.7
|
NYZ-15/3.7
|
WYZ-15/1.7
|
WYZ-15/3.7
|
|
240
|
185
|
NYZ-15/1.8
|
NYZ-15/3.8
|
WYZ-15/1.8
|
WYZ-15/3.8
|
|
300
|
240
|
NYZ-15/1.9
|
NYZ-15/3.9
|
WYZ-15/1.9
|
WYZ-15/3.9
|
|
400
|
300
|
NYZ-15/1.10
|
NYZ-15/3.10
|
WYZ-15/1.10
|
WYZ-15/3.10
|
|
500
|
400
|
NYZ-15/1.11
|
NYZ-15/3.11
|
WYZ-15/1.11
|
WYZ-15/3.11
|
|
|
Demands of order |
| All
the cable section, insulation
Dia. connecting wire thermal
material (Whole copper. aluminium)
should be signed. |

¡¡ |
|
 |
|
|
|
| ¡¡ |
|
¡¡ |
|